Low-Formaldehyde Boards: E0, E1 and CARB Emission Ratings for Plywood, MDF and HDHMR
What E1, E2, E0 and CARB P2 really mean for plywood, MDF and HDHMR, which labels Indian standards define, and how to check a board's emission class at delivery.

In this guide 10 sections
Plywood showrooms are full of "E0", "E1", "CARB certified" and "low-VOC" labels. They sound like a simple ladder from good to better, but each comes from a different standard, test and unit.
Here is what each label means for plywood, MDF and HDHMR, which ones Indian standards define, and how to check what you buy.
Why Boards Release Formaldehyde
Plywood, MDF, particle board and HDHMR are all wood veneer or wood fibre bonded with resin. Common resins include urea-formaldehyde (UF), phenol-formaldehyde (PF) and melamine-urea-formaldehyde (MUF). Some boards sold as no-added-formaldehyde use isocyanate (MDI) binders instead.
A finished board slowly releases some formaldehyde, depending on resin, finish, temperature, humidity and ventilation. The International Agency for Research on Cancer classifies formaldehyde as carcinogenic to humans (Group 1). That is a hazard classification, not a prediction about any one cabinet, but it is why emission classes exist.
E1 and E2: The Classes Indian Standards Define
Since February 2025, general-purpose plywood (IS 303:2024) and MDF (IS 12406:2025) can only be made or sold in India with a BIS Standard Mark. Both standards define two formaldehyde classes, measured by the perforator method in milligrams per 100 g of oven-dry board:
- E1: up to 8 mg/100 g. This is the stricter class.
- E2: above 8 and up to 30 mg/100 g.
IS 303:2024 requires licensed plywood to declare its formaldehyde class on the marking, along with the grade (MR, BWR or BWP), dimensions and month and year of manufacture. IS 710:2024 also added a formaldehyde requirement for marine plywood.
HDHMR has no Indian Standard of its own. It is a trade name for high-density, moisture-resistant fibreboard, and some boards sold as HDHMR are certified as HMR-grade MDF under IS 12406. If a sheet of HDHMR carries a BIS mark, it names that standard, grade and class. If it carries none, ask what it is certified as.
What "E0" Actually Means
"E0" is not a class in IS 303, IS 12406 or the European panel standard. In Indian showrooms it is mostly a marketing term suggesting emissions below E1. The board may well be low-emission, but the class you can hold a seller to is the E1 or E2 printed beside the ISI mark.
Where E0 is formally defined, it has its own numbers. China's GB/T 39600-2021 grades indoor panels as E0 when chamber emission is above 0.025 and not more than 0.050 mg/m³, and as ENF at 0.025 mg/m³ or below. That is a Chinese chamber test, not something you can read off an Indian perforator result.
European E1 and the New EU Furniture Limit
In Europe, E1 for wood-based panels is 0.124 mg/m³ in the EN 717-1 chamber test, or 8 mg/100 g by the perforator method.
Europe has since tightened the rules. From 6 August 2026, furniture and wood-based articles sold in the EU may not release more than 0.062 mg/m³ under the prescribed chamber conditions, half the E1 chamber figure. You may see this level described as "E0.5". So a European E1 sheet on its own no longer proves EU furniture compliance.
CARB Phase 2 and TSCA Title VI
CARB is the California Air Resources Board. Its Phase 2 limits, measured in a large chamber under ASTM E1333, are in parts per million:
| Product | CARB Phase 2 limit |
|---|---|
| Hardwood plywood (veneer or composite core) | 0.05 ppm |
| Particleboard | 0.09 ppm |
| MDF | 0.11 ppm |
| Thin MDF (8 mm or less) | 0.13 ppm |
The US federal TSCA Title VI rule uses the same values. The same rules allow NAF (no-added-formaldehyde) and ULEF (ultra-low-emitting formaldehyde) labels, but NAF still needs test evidence. Under the US rule, 90% of quality-control results must be at or below 0.04 ppm. "Formaldehyde-free" is a claim about the resin, not a promise of zero emission.
Why You Cannot Convert One Label into Another
Perforator results (mg/100 g), chamber results (mg/m³) and the American large chamber (ppm) are different tests. A CARB result is not an "E0 equivalent". Compare like with like.
| Label | Who defines it | How it is measured | Typical meaning |
|---|---|---|---|
| E1 (India) | IS 303:2024, IS 12406:2025 | Perforator, ≤8 mg/100 g | The stricter Indian class; ask for it in writing |
| E2 (India) | IS 303:2024, IS 12406:2025 | Perforator, >8 to 30 mg/100 g | Permitted, but higher-emitting |
| E1 (Europe) | EN 13986 | Chamber, 0.124 mg/m³ | European panel baseline |
| EU furniture limit ("E0.5") | REACH Annex XVII | Chamber, 0.062 mg/m³ | EU rule from 6 Aug 2026 |
| E0 (China) | GB/T 39600-2021 | Chamber, >0.025 to 0.050 mg/m³ | Only meaningful with a test report |
| E0 (showroom) | No Indian or EN class | Varies | Marketing term; ask for the test |
| CARB P2 / TSCA | California and US rules | Large chamber, ppm | Third-party certified for US markets |
Where Low Emission Matters Most at Home
A panel's class describes the board in a test chamber, not your room's air, which depends on how much board is installed, room size and ventilation. For indoor air, WHO's guideline is 0.1 mg/m³ over 30 minutes.
That points to a few practical priorities:
- Closed wardrobes and lofts hold a lot of board in a small, still volume.
- Children's rooms and bedrooms are where people spend the longest hours.
- Adhesives and finishes count too. Edge-banding adhesive and solvent-based paint also release VOCs, so water-based finishes and low-VOC adhesives help.
- Every component is separate. A shutter certificate does not cover the carcass, back panel or drawer base. Record each line.
There is no universal "safe after X weeks" timetable, and odour is not a measurement. For health concerns, take professional advice and consider indoor-air testing.
How to Check a Board at Delivery
- Find the ISI mark and the IS number, such as IS 303 or IS 12406.
- Read the marking: grade, formaldehyde class (E1 or E2), thickness, month and year of manufacture and batch number.
- Verify the licence. The CM/L number printed with the mark can be checked in the official BIS Care app under "Verify Licence Details".
- Ask for paperwork behind any E0 or CARB claim: the standard, test method, result, units and date for that exact product.
- Match the invoice. Brand, product, grade and class on the bill should match the sheets on site.
On cost, there is no reliable universal premium for lower-emission boards. Compare current quotes for the exact certified products, and do not pay extra for an "E0" label you cannot verify.
How Make My Space Approaches It
At Make My Space, every kitchen and wardrobe is built on a BWP plywood carcass, with a premium aluminium kitchen option where you want it. When you plan with us, ask your designer to list the board, grade and formaldehyde class for each part, from carcass to shutter, so you can check the markings when the sheets arrive. Modular kitchens start from ₹3.5 lakh and full home interiors start from ₹10 lakh, are completed in 45 days and come with a 10-year warranty.
FAQ
Is E0 plywood better than E1?
Not automatically. E0 is not an Indian or European class, so ask for the test report. In India, E1 is the stricter class you can verify on the marking.
Does HDHMR have a formaldehyde rating?
HDHMR has no Indian Standard of its own. Boards certified as HMR-grade MDF under IS 12406 carry an E1 or E2 class. Check the mark on the sheet.
Is CARB P2 the same as E1?
No. CARB Phase 2 uses a different chamber test and reports in ppm, with separate limits for plywood, MDF and particleboard. Neither converts directly into the other.
Are formaldehyde-free boards completely free of formaldehyde?
No. They use binders without added formaldehyde, but even US no-added-formaldehyde labels require test results, and finishes and adhesives can add their own emissions.
Planning your home interiors in Raipur? See our home interior design in Raipur.